DRO Milling Quill

Back

The installation of a DRO on the quill is very simple.

- Remove the two handles at the front side of the head.
- Remove the six screws of the front panel.
- Remove the nut of the original scale.
- Mount a metal plate below this nut.
- Mount the measuring staff with a clamp, delivered with the DRO (see picture).

The display is against the front panel with a small plate of metal and two bolds, so the front panel is pressed between this metal plate and the display.